Installation Guide Savi ST-618 Asset Tag
Published February 2009 Part number 805-05831-901 Rev A Documentation for SaviTag ST-618 Copyright © 2009 Savi Technology, Inc. All rights reserved. Unpublished - rights reserved under the Copyright Laws of the United States. EchoPoint, Savi, Savi SensorTag, Savi SmartChain, Savi SmartStart, Savi Technology, Savi’s Nested Visibility, SaviTag, SmartChain, the EchoPoint Logo, and the Savi Logo are trademarks or registered trademarks of Savi Technology, Inc. in the United States and other countries.
Contents 1 ST-618 Asset Tag Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Activating the Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Placing the Tag for Best Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Mounting the Tag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ST-618 Asset Tag Description The Savi ST-618 asset tag is a rugged active RFID tag ideally suited for locating, tracking, and managing medium to high value assets in both defense and commercial applications. The ST-618 carries enough memory to record asset configuration and maintenance records, and is ideal for these functions.
Savi ST-618 Asset Tag Installation Guide Features • ISO 18000-7 compliant active RFID asset tag • 2 Kbytes of memory for recording asset configuration and maintenance data • 400-foot (122m) range for wake-up, collections, and RF write/read operations • Replaceable battery with typical life of five years • FCC, HERO, ETSI, RoHS (Directive 2002/95/EC) certified Activating the Tag The tag is shipped in sleep mode. You must remove and re-insert the battery to wake up the tag.
Activating the Tag shown on the tag housing. The tag will not work if you install the battery in the wrong direction (reversed). Turn cap to close Correct battery orientation Whenever a battery is inserted into a tag, the tag will emit 5 beeps. Then, the tag will emit 2 short beeps to indicate adequate battery voltage or 3 short beeps if a fresh battery is required. Whenever a battery is inserted into a tag, the tag assumes that it is a fresh battery.
Savi ST-618 Asset Tag Installation Guide Improper Proper O-ring exposed O-ring hidden Turn cap until tight If the O-ring is not properly compressed by the cap, water leakage and damage may occur. Note: When the tag is not in use, disable the tag by removing, reversing, and re-inserting the battery. Store the battery at room temperature (50-80 °F or 10-27 °C ). Placing the Tag for Best Performance Savi Technology recommends that you mount the tag on a flat surface, with the tag aligned vertically.
Placing the Tag for Best Performance Typical locations include mounting the tag inside the middle of the container or on the outside of the container on a flat surface. For best performance, make sure the tag is: • Mounted on a metal surface. • Mounted at no less than a 6 foot (1.8m) elevation. • Mounted vertically. • Not mounted behind or between metal objects The next figure shows an example of a tag mounted on an ISO container according to the performance guidelines.
Savi ST-618 Asset Tag Installation Guide • at 20 feet (6m) or higher caution: Tags mounted close to the ground may have less range. Follow the instructions in the Savi Fixed Reader documentation to locate and position the Savi Fixed Reader for best performance. Mounting the Tag You can choose among several mounting methods for the tag, including using pressure sensitive tape (PST) or a plastic mounting sleeve.
Mounting the Tag Pressure sensitive tape The magnetic mount clamps directly onto the metal surface. The magnets hold the tag securely, but allow the tag and the magnetic bracket to be removed quickly. Once a mounting sleeve is fastened to an asset, you can leave it on the asset even after the tag is removed so it is available for future use with other compatible tags. Prior to re-use, visually inspect the PST-mounted sleeve to make sure it is attached securely.
Savi ST-618 Asset Tag Installation Guide Security hole Replacing the Battery The tag is equipped with non-volatile memory, which means stored data is not lost when you replace the battery. 1. Remove the battery cap. 2. Remove the discharged battery from its compartment For more information, see “Activating the Tag” on page 6. Note: The lithium battery can be harmful to the environment. Follow current procedures for safely disposing of lithium batteries. The battery cannot be reused or recharged. 3.
Contacting Savi Support Whenever a battery is inserted into a tag, the tag assumes that it is a fresh battery. Inserting a used battery into a tag may result in what appears to be a premature battery failure. After the beep, continue tightening the cap until it is secure. Contacting Savi Support If you cannot find the information you need, contact Savi Support Services. • Check http://supportcenter.savi.com for contact information. • Send an email to help@savi.com.
Savi ST-618 Asset Tag Installation Guide Specifications Model Numbers ST-618-030: Asset Tag ST-618-032: Asset Tag ST-618-032-NSN: Asset Tag with label Physical Characteristics Dimensions: 6.2 in. (15.8 cm) x 2.1 in. (5.4 cm) x 1.1 in. (2.8 cm) Weight: 3.
Specifications Power Battery type: 3.6 volt lithium-ion, replaceable by user without tools Battery life: Approximately 5 years at 2 collections per day Power management: UHF sleep mode prevents unwanted collections, enabled/disabled by LF link.
Savi ST-618 Asset Tag Installation Guide 16