Published February 2009 Part number 805-05826-901 Rev A Documentation for SaviTag ST-654 Copyright © 2009 Savi Technology, Inc. All rights reserved. Unpublished - rights reserved under the Copyright Laws of the United States. EchoPoint, Savi, Savi SensorTag, Savi SmartChain, Savi SmartStart, Savi Technology, Savi’s Nested Visibility, SaviTag, SmartChain, the EchoPoint Logo, and the Savi Logo are trademarks or registered trademarks of Savi Technology, Inc. in the United States and other countries.
Contents 1 Savi ST-654 Data-Rich Tag Description . . . . . . . . . . . . . . . . . . . 5 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Activating the Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Initializing the Tag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Placing the Tag for Best Performance . . . . . . . . . . . . . . . . . . . . . . . . . . .
Savi ST-654 Data-Rich Tag Description The Savi ST-654 high performance, data-rich active RFID tag is suited for various applications, including tracking shipping containers, vehicles, and other large assets.
Savi ST-654 Data Rich Tag Installation Guide Features • ISO 18000-7 compliant active RFID data-rich tag • 128 Kbytes of programmable database memory enables tag to support multiple applications • 400-foot (122m) omnidirectional line-of-sight range • Replaceable battery with a typical life of five years • Supports low-frequency technology for more precise locating capabilities • Supports USB for reading and writing • FCC, HERO, ETSI, RoHS (Directive 2002/95/EC) certified Activating the Tag The
Activating the Tag 2. Remove the battery. Wait a few seconds and then reinsert the battery, matching the negative (–) and positive (+) terminals to the symbols shown on the tag housing. The tag will not work if you install the battery in the wrong direction (reversed). Turn cap to close Correct battery orientation Whenever a battery is inserted into a tag, the tag will emit 5 beeps.
Savi ST-654 Data Rich Tag Installation Guide Improper Proper O-ring exposed O-ring hidden Turn cap until tight If the O-ring is not properly compressed by the cap, water leakage and damage may occur. Note: When the tag is not in use, disable the tag by removing, reversing, and re-inserting the battery. Store the battery at room temperature (50-80 °F or 10-27 °C ). Initializing the Tag Once you activate the tag, you can initialize it for immediate use. 1. Unplug the USB port cover. 2.
Placing the Tag for Best Performance USB cable USB port 3. Refer to the Savi SmartChain Mobile User Guide or the Savi Smart- Chain WorkStation User Guide for instructions on the initialization process. Placing the Tag for Best Performance Savi Technology recommends that you mount the tag on a flat surface, with the tag aligned vertically.
Savi ST-654 Data Rich Tag Installation Guide as possible, safe from impact (for example, between the ribs of an ISO-type shipping container), and away from obstructions on the asset. Mount the tag by adhering the tag and supplied plastic mounting sleeve with pressure sensitive tape (PST) to the inside or outside of a Class VIII container or plastic, cardboard, or wood container or box.
Mounting the Tag The tag will have 400-foot (122m) read/write range to Savi SR-650 Fixed Readers. For the most consistent communications with the tag, the Fixed Readers must be mounted: • to have an unobstructed line-of-sight to the tag • at 20 feet (6m) or higher caution: Tags mounted close to the ground may have less range. Follow the instructions in the Savi Fixed Reader documentation to locate and position the Savi Fixed Reader for best performance.
Savi ST-654 Data Rich Tag Installation Guide For ease of installation, the tag comes with this PST on the back of the plastic mounting sleeve. PST mounting kits are also available for separate purchase. Pressure sensitive tape The magnetic mount clamps directly onto the metal surface. The magnets hold the tag securely, but allow the tag and the magnetic bracket to be removed quickly.
Replacing the Battery Security hole Replacing the Battery The tag is equipped with non-volatile memory, which means stored data is not lost when you replace the battery. 1. Remove the battery cap. 2. Remove the discharged battery from its compartment. For more information, see “Activating the Tag” on page 6. The lithium battery can be harmful to the environment. Follow current procedures for safely disposing of lithium batteries. The battery cannot be reused or recharged. 3. Install a 3.
Savi ST-654 Data Rich Tag Installation Guide Whenever a battery is inserted into a tag, the tag assumes that it is a fresh battery. Inserting a used battery into a tag may result in what appears to be a premature battery failure. After the beep, continue tightening the cap until it is secure. Contacting Savi Support If you cannot find the information you need, contact Savi Support Services. • Check http://supportcenter.savi.com for contact information. • Send an email to help@savi.com.
Specifications Specifications Model Numbers ST-654-031: Data-rich tag ST-654-031-NSN: Data-rich tag with label Physical Characteristics Dimensions: 6.2 in. (15.8 cm) x 2.1 in. (5.4 cm) x 1.1 in (2.8 cm) Weight: 3.
Savi ST-654 Data Rich Tag Installation Guide Accessories Mounting: • Pressure sensitive tape • Savi Mounting Kit SRA-1260-Green (sold separately) • Savi Magnetic Mounting Kit STA-1261-Green (sold separately) Approvals 16 Radio Type Approval: FCC Part 15, EN 300 220 (433 MHz) EMC and Immunity: EN 301 489 Ordnance: HERO Certified, ARDEC rating of 1 in. (2.