Installation Guide Savi Fixed Reader SR-650-101 Version 1.
Published May 2008 Part number 805-04399-001 Rev C Documentation for Savi Fixed Reader SR-650-101 Copyright © 2008 Savi Technology, Inc. All rights reserved. Unpublished rights reserved under the Copyright Laws of the United States. EchoPoint, Savi, Savi SensorTag, Savi SmartChain, Savi SmartStart, Savi Technology, SaviTag, SmartChain, the EchoPoint Logo, the Savi Logo, the UDAP Logo, and UDAP are trademarks or registered trademarks of Savi Technology, Inc. in the United States and other countries.
FCC Registration Required for Operation under Rule 15.240 Radio transmissions from the SR-650-101 are governed in the US by FCC Part 15 rules, and in Canada by corresponding Industry Canada regulation RSS-210 . Still other regulations apply in Europe and other countries. The SR-650-101 is shipped with the default mode of operation corresponding to FCC 15.231. All prior Savi equipment complies with 15.231. Equipment operating under this rule does not require FCC Registration. FCC Rule 15.
FCC RFID REGISTRATION FORM FOR FCC RULE 15.240 To: Experimental Licensing Branch, OET Federal Communications Commission 445 12th Street, SW Washington, DC 20554 ATTN: RFID Registration Subject: Registration for Savi Technology, Inc. Model SR-650-101 RFID Fixed Interrogator The following information concerning the end user and installation location is hereby submitted as required by FCC Rule 15.
Contents 1 Introduction Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Reader Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Network Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Tag Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Models and Options . . .
Adding a Reader Manually Using an Ethernet Connection . . . 31 Setting the Host IP and Synchronizing Time . . . . . . . . . . . . . . 32 Configuring the Reader with Savi Retriever Using a SaviNet Connection (RS-485) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Verifying Reader Communication . . . . . . . . . . . . . . . . . . . . . . . . . 34 4 Installing the Savi Fixed Reader Positioning the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER Introduction 1 1 You can use the Savi® Fixed Reader SR-650-101 to scan, detect, and collect tag information. The SR-650-101 reader is designed to communicate with all models of SaviTags, and forward the collected data to the Savi SmartChain® Site Manager or SmartChain® Client Tools host platforms. You can network multiple readers to cover large facilities.
CHAPTER 1 Introduction Features ◆ Long-range, omnidirectional communication enables effective monitoring of thousands of tagged items over a 328-foot (100 meters) radius—ideal for yards, terminals, and warehouses. ◆ Ethernet connectivity supports wired and wireless installations, allowing multiple readers to be easily networked together. ◆ Universal Data Appliance Protocol™ (UDAP™) provides interoperability with other data collection devices, including bar code scanners and other RFID readers.
Reader Description Tag Communication The Savi Fixed Reader SR-650-101 can transmit control commands and data over a UHF link to SaviTags. In return, the SaviTags transmit status information, recognition codes, and data over the UHF link to the reader, depending on the commands the tag received.
CHAPTER 1 Introduction Specifications The Savi Fixed Reader SR-650-101 can be mounted in permanent or semipermanent sites, as well as in a mobile vehicle. SR-650-101 readers are designed for indoor or outdoor use. Specification Description Physical characteristics Length: 12 inches (30.48 cm) in diameter Height: 7 inches (17.78 cm) Weight: 4.2 pounds (1.
Reader Description Specification Description Network Interface: ✦ UDAP protocol over Ethernet 10Base-T ✦ Reader network supports wireless connectivity to host computer via external 802.
CHAPTER 1 Introduction Specification Description Regulatory requirements Radiated emission (intentional): U.S. emission standards as contained in FCC Part 15 Canada RSS210 European Community emission standards as contained in EN 300 220 (433 MHz) Electromagnetic Immunity: ESD compliance Exposed to 8 kV air discharge or 4 kV contact discharge in accordance with EN 301 489-1 Radiated emission (unintentional): U.S.
Reader Description Models and Options Savi fixed readers are supplied with cables necessary for operation. Available accessories include a solar power unit, a vehicle power cable, the AC power adapter and cables, spare batteries, a battery charger, and mounting hardware. Contact your Savi Customer Service representative for information about ordering additional equipment or accessories. The table shows Savi Fixed Reader SR-650-101 models and options.
CHAPTER 12 1 Introduction Model Description Power/Plug SR-650-101-2E Savi Fixed Reader SR-650-101, Ethernet cable 92-250 VAC 50/60 Hz, European Plug SR-650-101-3E Savi Fixed Reader SR-650-101, Ethernet cable 92-250 VAC 50/60 Hz, Japan Plug SR-650-101-6E Savi Fixed Reader SR-650-101, Ethernet cable 92-250 VAC 50/60 Hz, Type 2 Plug SR-650-101-7E Savi Fixed Reader SR-650-101, Ethernet cable 92-250 VAC 50/60 Hz, U.K.
Contacting Savi Global Support Services Contacting Savi Global Support Services If you cannot find the information you need, contact Savi Global Support Services. Check www.savi.com/services/su.contact.shtml for contact information. ◆ Send email to help@savi.com. ◆ Call 1-888-994-7284 (North America only) or 650-316-4760 between 5 a.m. and 5 p.m. Pacific time.
CHAPTER 14 1 Introduction Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER 2 Designating Locations and Connecting Cables 2 Before physically installing the Savi Fixed Reader SR-650-101, you must: 1. Consult a site plan to determine the reader’s installation location. 2. Connect power cables and network cables. 3. Supply power. Planning a Site To plan a site you must conduct a site survey and plan the RFID network configuration. Once the site plan is in place, refer to it to determine where to install Savi fixed readers.
CHAPTER 2 Designating Locations and Connecting Cables You can also power the Savi Fixed Reader SR-650-101 from a Savi Solar Power Module or by vehicle power. A fixed-length, molded cable is supplied with the Solar Power Module. You can purchase the Vehicle Power Cable as an accessory. To connect the power cable to the reader: 1. If you are installing the Savi Fixed Reader SR-650-101 in an outdoor location, slide heat shrink tubing onto the power cable before connecting the cable to the reader. 2.
Connecting Power Cables to the Savi Fixed Reader Figure 2-2 Power cable Connector shell Plug to AC outlet 3. Ensure that the heat shrink tubing is protecting the power cable’s connector shell. Position the heat shrink tubing so it is not completely against the reader’s connector panel and covering the entire connector shell but is .25 of an inch (6.35 mm) from the connector panel. 4.
CHAPTER 2 Designating Locations and Connecting Cables Connecting the Network Cables Before you connect the Savi fixed reader’s network cables, check relevant configuration or wiring diagrams. Note: The Savi Fixed Reader SR-650-101 is rated for use in severe environments. For additional precautions, Savi recommends the use of heat shrink tubing (Savi part number 680-02423-001) for units subject to outdoor use.
Connecting the Network Cables Note: The SaviNet cable with converter is provided with Savi software (such as Savi Retriever) since only one computerconnector cable is required per network. The SaviNet cable is also available separately (Savi part number 830-00911-001). Figure 2-3 RS-485 ports Network In (RS-485 port) Network Out (RS-485 port) 3. Push the locking ring forward firmly and rotate clockwise to lock the connector. 4.
CHAPTER 2 Designating Locations and Connecting Cables Connecting Two or More Savi Fixed Readers If you are connecting several Savi fixed readers in a daisy chain configuration, use a standard Savi-provided network cable to connect each reader, as shown in Figure 2-4. Figure 2-4 Savi fixed readers in daisy chain configuration Network Out Network In Network Out Network In Network Out Network In 4 2 1 To Host Computer 3 Network In Network Out To connect the multiple Savi fixed readers: 1.
Connecting the Network Cables 5. Continue to link new readers as necessary (cables 3 and 4 in Figure 2-4). The final reader in the chain must be terminated with a matched resistive load (termination cable assembly) to prevent signal reflections in long cable runs. Note: The termination cable assembly (Savi part number 830-04598-001) is included with the reader. If the distance between readers is greater than 100 feet (30.
CHAPTER 2 Designating Locations and Connecting Cables To connect the Savi Fixed Reader SR-650-101 to an Ethernet hub: 1. Connect an RJ-45 connector to the Ethernet cable. The other end of the Ethernet cable includes an RJ-45 connector with a protective connector shell.
Connecting the Network Cables 2. Cover the RJ-45 connector with an RJ-45 sleeve. Connect this end of the Ethernet cable to the Ethernet hub. Figure 2-6 RJ-45 connector and sleeve 3. Remove the protective cap from the Ethernet port on the Savi Fixed Reader SR-650-101.
CHAPTER 2 Designating Locations and Connecting Cables 4. Connect the RJ-45 connector with the connector shell into the Ethernet port. Figure 2-8 Connected Savi Fixed Reader SR-650-101 Note: Replace and tighten the protective cap when the Ethernet port is not used.
Applying Power to the Savi Fixed Reader Applying Power to the Savi Fixed Reader After connecting power and network cables, apply power to the reader by connecting the male connector end of the power cable to the appropriate power source, such as the Savi Solar Power Module or an AC outlet. Figure 2-9 Savi Fixed Reader SR-650-101 LED display panel LED display panel To confirm that power is present in the reader: 1. Observe the indicators on the LED display panel.
CHAPTER 2 Designating Locations and Connecting Cables c. After the ID display, the reader’s default IP address appears in the LED display. Savi fixed reader IP address 10.7.19.11 displays: IP, then =, then 10, then 7, then 19, and then 11 in sequence. Note: Upon changing the reader’s default IP address, the reader’s new IP address appears in the LED display. To change the reader’s IP address, see “Adding and Configuring the Reader in SmartChain Site Manager” on page 29. d.
CHAPTER Managing the Reader Network 3 3 The Savi Fixed Reader SR-650-101 communicates with the SmartChain Site Manager host computer, using the SaviNet (RS-485) or Ethernet protocols. When the reader communicates with the Savi Retriever host computer, only the SaviNet (RS-485) protocol is required. This chapter provides the information you need to manage and configure your Savi Fixed Reader SR-650-101 with the appropriate host computer.