User's Manual

CHAPTER 4
Installing the Savi Fixed Reader
36 Savi Fixed Reader SR-650-101 Installation Guide
Figure 4-1 Impediment limiting the Savi Fixed Reader SR-650-101 collection range
If the location forces you to use a less-than-ideal position for the reader,
the collection range could be reduced, requiring additional readers.
Note:
If you must mount a Savi fixed reader on a wall, the collection range
may not extend to the opposite side of the wall. You may need a second
Savi fixed reader to monitor the area behind the wall.
The collection range of the equipment depends on surrounding obstructions
that may shield tags from receiving reader signals or cause reflections into
locations outside the line of sight. As a first step, it is best to identify reader
installation locations using a line of sight model to any assets equipped with
tags. You may need to experiment to cover the desired area.
To optimize performance:
Locate the reader at least 20 feet (6.1 meters) above the ground.
Avoid installations within 6 feet (2 meters) of metal surfaces, such as
temporary buildings or large steel doors.
Area of
limited
collection
ability
Metal wall
Savi fixed reader
mounted near a
ceiling