Appendix A
Savi Fixed Reader SR-650-101 Installation Guide 53
3. Type timeoutntp=8 (unit: minutes) and press Enter to set the period
(in minutes) for which, if the reader has not received time information,
it will assume it has lost time synchronization with the NTP server.
Figure A-19 Telnet NTP server time out command
4. Type aheadtime=2 (unit: seconds) and press Enter to set the time
(in seconds) of the reader ahead of the synchronized NTP server time.
Figure A-20 Telnet reader ahead time command
5. Type now? and press Enter to display the current time.
If the reader is not set to synchronize with an NTP server, then you can
also set the time with this command.