User's Manual

Typical locations include mounting the tag inside the middle of the container or on the outside of the container on a at
surface.
For best performance, make sure the tag is:
Mounted on metal surface
Mounted at no less than a 6 foot (1.8m) elevation
Mounted vertically
Mounted horizontally
Not mounted behind or between metal objects
The gure shows a tag mounted on an ISO container according to the performance guidelines.
Note: Make sure you clean the surface of the container or other asset before attaching the tag.
The tag has 300-foot (100m) read/write range to Savi SR-650 Fixed Readers. For the most consistent communications
with the tag, the readers must be mounted:
to have an unobstructed line-of-sight to the tag
at 20 feet (6m) or higher
Caution: Tags mounted close to the ground may have less range.
Follow the instructions in the Savi SR-650 Fixed Reader Installation Guide to locate and position the Savi Fixed Reader
for best performance.
Placing the Tag on Aircraft Pallets
Place the tag at least 6 inches (15.24 cm) above ground level, on the long side of the pallet (for example, the 108-inch
side of a 108 x 88 inch 463L pallet) to avoid forklift damage. Mount the tag in the middle of the rail of the pallet, directly
above one of the tabs (or dog ears) that protrude from the rail.
OpenTopic | Savi ST-616 Asset Tag Description | 7
XML to PDF by RenderX XEP XSL-FO Formatter, visit us at http://www.renderx.com/