User's Manual

0RXQWLQJWKH6LJQSRVWV
(FKR3RLQW6LJQSRVW,QVWDOODWLRQ*XLGH 
&DEOLQJWKH0RGHO636LJQSRVW
The connectors and LED shown in Table 2-4 are available on a Model
SP-600-101 Signpost.
» To cable a Model SP-600-101 Signpost
1. Cable the Model SP-600-101 the same as the Model SP-600-201.
For cabling, the Model SP-600-101 is identical to the cabling
for the Model SP-600-201 except that the Model SP-600-101
has an internal antenna.
See Cabling the Model SP-600-201 Signpost on page 2-10.
2. Continue with configuration using the Signpost configuration
software.
See Configuring Signpost Operation Settings on page 3-3.
7DEOH 0RGHO636LJQSRVW&RQQHFWRUVDQG/('V
Connectors
and LEDs
Description
Power The input power is connected here.
RS-232 Used to connect to a computer for setup and diagnostics by installers
and technicians.
Sync In Used to synchronize 2 to 4 Model SP-600-101 Signposts to cover an
area larger than is possible with a single Signpost. This connector can
also accept DC volts from another Signpost to avoid running separate
power lines when two or more Signposts are synchronized
Sync Out Used to synchronize 2 to 4 Model SP-600-101 Signposts to cover an
area larger than is possible with a single Signpost. This connector can
also output DC volts to another Signpost to avoid running separate
power lines when two or more Signposts are synchronized
Sensor 1 A closure on these two pins will trigger a predefined Signpost action.
Sensor 2 A closure on these two pins will trigger a predefined Signpost action.
Status This LED indicates when power is applied and the Signpost mode of
operation:
On ½ second, off ½ second indicates normal operation
On 1 second, off 1 second indicates the Signpost is off but powered
On continuously indicates the Signpost is transmitting a CW signal