User's Manual

9HULI\LQJ5HDGHU&RPPXQLFDWLRQ
 (FKR3RLQW5HDGHU65,QVWDOODWLRQ*XLGH
9HULI\LQJ5HDGHU&RPPXQLFDWLRQ
To confirm that an EchoPoint Reader SR-600-101 is installed and
functioning correctly, it is necessary to verify that the Reader:
Can communicate with the computer (verifies that the reader
is detected on the network)
Can collect tags in the collection area
Can communicate with each specific tag in the collection area
Once the EchoPoint Reader is installed, run the asset management
software to locate the reader. If the program does not detect the
reader, use a computer with an installed test program (such as
Savi ToolsSavi part number 861-01235-001) to perform the
following procedures verifying EchoPoint Reader
communications:
» To verify reader communications:
1. If using Savi Tools, connect the laptop or computer to the
RS-232 port and start the software program.
2. Verify that the selected EchoPoint Reader appears on the
network.
3. Confirm that the EchoPoint Reader communicates with tags
by performing a tag collection.
4. Verify that the EchoPoint Reader communicates with specific
tags by attempting to beep each tag.
Refer to the reference material accompanying the test program
software for specific instructions on performing the above
functions. When these procedures have been completed
successfully, the EchoPoint Reader is installed and operational.