Installation manual

Installation and servicing instructions strictly reserved for qualified gas installers
55
Combustion
Fresh air flow rate (1013 mbar - 0°C) m3/h 43
Product
outlet flow rate g/s 15.3
Product
outlet temperature °C 68
V
alues of product outlet (measured on nominal heating output with G20 reference gas):
CO
ppm 86
mg/kWh 92
CO2
% 9.2
NOx balance
ppm 21.1
mg/kWh 37.3
Dimensions:
Height mm 890
Width mm 700
Depth mm 480
Net
weight kg 75
W
eight of appliance when full kg 120
Supply
voltage V/Hz 230/50
Maximum
absorbed power W 241
Electrical
rating A 1.05
Fuse mA 630
Electric
protection IPX4D
Class 1
CE
number 1312 BP 4108
Technical data depending on the gas type Unit ISOTWIN CONDENS F 35 E
Natural gas G 20 (1)
Sanitary flow rate at maximum input
m
3
/h
3.62
Heating flow rate at maximum input
m
3
/h
3.02
Flow
rate at minimum input
m
3
/h
0.68
Inlet pressure mbar 20
Burner
injector diameter mm 5.65
(1) 15 °C, 1013,25 mbar