Installation manual

52
15.4 Condensate trap
1
2
4
3
5
6
Legend
1 Flexibles
2 Float
3 Condensate trap retaining screw
4 Condensate trap
5 Draining flexible
6 Siphon adapter
Disconnect the connector flexible (5)
located under the condensate trap.
Remove the front face of the tight
chamber
.
Loosen both retaining screw (3) of the
condensate trap (4).
Remove the condensates recovery
equipment by loosening fl
exibles (1);
take care do not spray liquid.
Warning: condensate is acidic: use
protective gloves.
•
•
•
•
Fit the new condenstae trap in the
reverse order
.
15.5 Control panel
15.5.1 Access to the printed circuit
board
1
2
Legend
1 Switchbox protective cover retaining
screw
2 Cover retaining plate on the switchbox
Remove the 2 switchbox protective
cover retaining screws (1).
Remove the cover retaining plate on
the switchbox (2).
Remove the switchbox protective cover
.
•
•
•
•