Operator`s manual
Table Of Contents

Reserved (DSW2-4) - Reserved for future use.
Receive Buffer Selection(DSW2-5) - Selects the operating mode of the receive
buffer. See Section 6: Interface Specifications for more information.
Reserved (DSW2-6) - Reserved for future use.
Protocol Code Selection (DSW2-7) - Selects the command codes used for
protocol control. Refer to page E-1for more information.
Pitch Size Check (DSW2-8) - Checks the length on the installed media against the
size loaded via software (<ESC>A1 Command, page 5-46).
Reserved (DSW3) - Reserved for future use.
Note: The Centronics (Parallel) communications port is always enabled regardless of the
settings for the RS232 port. There are no settings for Centronics! Both the Centronics
and RS232 ports are active at all times. Care should be taken to ensure that data is not
transmitted to both ports simultaneously as the received message will be corrupted.
DSW2-5 SETTING
Off Single Job
On Multi Job
12345678
ON
OFF
DSW2
DSW2-7 SETTING
Off Standard
On Non-Std
12345678
ON
OFF
DSW2
DSW2-8 SETTING
Off Disabled
On Enabled
12345678
ON
OFF
DSW2
Section 3. Printer Configuration
Page 3-49001038 Rev. DSATOXL SeriesPrinters