Operator`s manual
Table Of Contents

Interleaved Two of Five (I 2/5)
Command Structure 1:3 ratio: <ESC>B2bbccc (data)
2:5 ratio: <ESC>BD2bbccc (data)
1:2 ratio: <ESC>D2bbccc (data)
bb = Width of narrow element in dots (01-12)
ccc = Bar height in dots (001-600)
(data) = Bar code data (numeric); must be an even number of digits
or else the printer will add a leading zero; start and stop
code are provided by the printer
Character Set 0-9 (numeric only)
Density Table
Printer
Model
Narrow/
Wide
Ratio
Value of
“bb”
“X”
Dimension
(mils)
Density
(char/inch)
XL410
1:3 01 3.3 33.4
1:3 02 6.7 16.7
2:5 01 3.3 18.8
1:2 01 6.7 21.4
1:2 02 3.3 14.3
XL400
1:3 01 5.0 22.6
1:3 02 10.0 11.3
2:5 01 10.0 12.7
1:2 01 5.0 14.5
1:2 02 10.0 9.7
Example <ESC>H0100<ESC>V0100<ESC>B20310045676567
<ESC>H0140<ESC>V0210<ESC>XM45676567
Notes To add horizontal guard bars to the top and bottom of the bar code,
use the Line and Box command (see page 5-42).
Appendix B: Bar Code Specifications
Page B-49001038 Rev. DSATOXL SeriesPrinters