Operator`s manual
Table Of Contents

2-D BAR CODES
BKaabbcdd
eeefffnn...n
PDF417. Prints PDF417 2-D symbols.
aa = Minimum module dimension (03-09 dots). Will not print
for values of 01, 02 or 10.
bb = Minimum module pitch dimension (05-240 dots). Will not
print for values of 01, 02, 03 or greater than 25.
c = Security level (1-8).
dd = Code words per line (01-30). If 00 is specified for dd
and
ee, printer
will automatically optimize settings.
ee = Rows/symbol (00 or 03). If 00 is specified for dd
and
ee, printer will
automatically optimize settings.
fff = Number of characters to be encoded (0001-2700)
nn...n = Data to be printed.
Page 5-
BUaaa,bbb,
cccccc,dddd,
ee...e
Maxicode. Prints 2-D Maxicode symbols.
aaa = Service class, numeric only (001-999).
bbb = Country code, numeric only (001-999).
cccccc= ZIP code, alphanumeric (000000-999999).
dddd = Extended ZIP code, numeric only (0001-9999)
ee...e = Low priority message, alphanumeric, 84 characters.
Page 5-
BXaabbccdd
eeefffghh
Data Matrix - Data Format. Specifies the format of the Data Matrix
2-D symbology.
aa = Format ID (01-16, The values 07 and 17 will not be accepted)
bb = Error correction level (00, 01, or 05-14, the values 02, 03 or ≥ 15
will not be accepted).
cc = Horizontal cell size (03-12 dots/cell)
dd = Vertical cell size (03-12 dots per cell)
eee = Cells per line. Must use 000 for optimized symbol.
fff = Cell lines. Must use 000 to optimize.
g = Mirror image
0 Normal Print
1 Reverse Print
hh = Guide cell thickness (01-15) 01 indicates normal type.
Page 5-
DCxx...x Data Matrix- Print Data. Prints data using Data Matrix format specified
in BX Data Format command.
xx...x = Data to be printed. Cannot exceed 500 characters.
Page 5-1
FXaaabccc
dddeee
Data Matrix - Sequential Numbering. Prints sequential numbered
Data Matrix 2-D symbols.
aaa = Number of duplicate labels (001-999)
b = Increment or decrement
+ Increment
- Decrement
ccc = Increment/decrement steps (001-999)
ddd = Sequential numbering start position (001-999). Referenced
to left side.
eee = Incremented data length (001-999). Measured from start
position.
Page 5-1
INSTRUCTION DESCRIPTION PAGE
Appendix A: Command Code Quick Reference
SATOXL SeriesPrinters9001038 Rev. DPageA-11