Operator`s manual
Table Of Contents

Faaaabcccc
ddee
Sequential Numbering. Allows the printing of sequencing fields (text,
bar codes) where all incrementing is done within the printer.
aaaa = Number of times to repeat the same data (0001-9999)
b = Plus or minus symbol (+ for increments; - for decrements)
cccc = Value of step for sequence (001-9999)
dd = No. of digits for sequential numbering (01-99, default = 8)
ee = No. of digits free from sequential numbering (01-99, default = 0)
Page 5-61
FWaaHbbbb Horizontal Line. Prints a horizontal line. Units of measurement are
dots.
Page 5-42
XL400 XL410
aa = Width of Horizontal Line 01 to 99
bbbb = Length of Horizontal Line 0001-0800 0001-1200
FWaabbVccc
Hdddd
Box. Prints a box. For values aa, bbbb, cc, and dddd, see instructions
for horizontal and vertical lines. Units of measurement are dots.
Page 5-42
XL400 XL410
aa = Width of Horizontal Side 01 to 99
bb = Width of Vertical Side 01 to 99
cccc = Length of Vertical Side 0001-1920 0001-2880
dddd = Length of Horizontal Side 0001-0800 0001-1200
FWccVddd Vertical Line. Prints a vertical line. Units of measurement are dots. Page 5-42
XL400 XL410
cc = Width of Vertical Line 01 to 99
dddd = Length of Vertical Line 0001-1920 0001-2880
Gabbbccc(data) Custom Graphics. Allows the creation and printing of graphic images
using a dot-addressable matrix.
a = Specifies format of data stream to follow
B Binary
H Hexadecimal
data = Data to describe the graphic image
Page 5-38
XL400 XL410
bbb Horizontal Blocks 001 - 100 001 - 150
ccc Verticval Blocks 001 to 240 001 - 360
GPaaaaa PCX File. Downloads PCX file to the internal graphics image memory.
aaaaa = No. of bytes to be downloaded (max DOS file size = 32K)
Page 5-40
INSTRUCTION DESCRIPTION PAGE
Appendix A: Command Code Quick Reference
SATOXL SeriesPrinters9001038 Rev. DPage A-3