Operator`s manual

Example of correct data stream:
<ESC>A
<ESC>GIHaaabbb001(DATA)
<ESC>Z
<ESC>A
<ESC>GIHaaabbb002(DATA)
<ESC>Z
Example of incorrect data stream:
<ESC>A
<ESC>GIHaaabbb001(DATA)
<ESC>GIHaaabbb002(DATA)
<ESC>Z
5. Do not use ASCII <CR> or <LF> characters (carriage return or line
feed) as line delimiters within the graphic data or the actual image
will not be printed as specified.
6. The graphics storage number (ddd) must be specified with this
command.
7. The allowable vertical and horizontal settings are:
XL400 XL410
Horizontal Blocks
cccc
001to100 001to150
Vertical Blocks
cccc
001to240 001to360
Section 5. Programming Reference
SATOXLSeriesPrinters9001038Rev.DPage5-81