Instruction manual
Section 3: Configuration and Operation
TH2 Series Operator Manual Page 3-73
3.8 ADVANCED SETUP MENU (Cont’d)
Menu Description
Displays existing USB NUMBER selection and enables new selection.
1.Default
If Default is selected, all printers will appear at the same Comm.Port at the PC
Host.
2.Unique
At PCB manufacturing, the main PCB is given a serial number. This number is
stored in the printer and will be used as a USB serial number if Unique is
selected.
Enables the selection of 8.Disp adj. / Cutter adj. from ADV SETUP menu.
The printer will enable adjusting of the TPH to dispensing plate (tear edge) dis-
tance.
Note: If a cutter is installed, the menu choice will be 8.Cutter adj.
Input correct adjustment value based on the stop and/or cut position.
Note: For input of negative value; input the numbers first and then the minus-
sign.
Feed a label to see where the selected setting stops it.
The default settings is 0.
When selecting 9.Continue from ADV SETUP menu, the printer will exit the
Advanced Setup menu and continue start up and proceed to PRINT menu.
If RESET is performed before selecting and confirming Continue, the printer will
reboot.