Instruction manual
Section 3: Configuration and Operation
Page 3-46 TH2 Series Operator Manual
3.7 PRINTER SETUP MENU (Cont’d)
Menu Description
7. If calibration is successful, the screen on the left is displayed, press
enter button to proceed.
8. Select Yes to confirm calibration result and save the sensor values.
Select No to regret calibration result. The sensor values will not be saved.
MEDIA menu.
Enables the selection of 1.Size, 2.Sensor Type, 3.Calibrate or 4.Max feed.
Select 4.Max feed.
MAX FEED sets the maximum feed length to feed before generating “Gap not
found” or “I-mark not found”. Normally, the default value can be used for all
media and format sizes.
In certain applications, it is important to be notified about label detection prob-
lems as soon as possible. Then MAX FEED should be set to the physical label
length.
MAX FEED must always be at least as long as the physical media length.
Displays the media MAX FEED range and input field with existing value and
unit.
Enables input of new media MAX FEED length.
Setting range is between 128 and 1880, and the default value is 1872 dot.
Note:
If the value is outside the allowed range, Invalid will be displayed.
If the value is acceptable, Saved will be displayed when enter button is
pressed.