To calibrate the feed gap or black mark sensor perform the following steps:
1. Turn the printer OFF.
2. Hold down FEED and PAUSE and turn the machine on.
3. The printer will read (1)DIAG.
4. Press the RESTART key until (5)SENSOR ADJ appears.
5. Press PAUSE and [H] and [A] will appear.
6. Press PAUSE and [S] will appear.
7. Press Pause and [REFLECT] will appear.
This is the sensor setting for the reflective black mark sensor:
Slide the notched tags under the sensor and hold down the
RESTART key until an asterisk (*) appears. The voltage should
read between 4.5 and 4.7. Then press PAUSE and [TRANS] will
appear. If only calibrating the black mark sensor you can shut
the machine off and turn it back on to get ready to print.
8. Press PAUSE and [TRANS] will appear.
This is the sensor setting for the feed gap sensor: Take about
10 inches of labels and take all of the labels off of the backing
paper. Slide the backing paper under the sensor. Press and
hold the RESTART key until an asterisk (*) appears. The
voltage should read between 4.5 and 4.7. Then press PAUSE
and [PE] will appear. If you are calibrating the feed gap sensor
only you can skip step 7.
For the sensor alignment the sensor must be placed according to the picture
depending on what kind of media is being used.