2.9 Sensor Calibration and Alignment
The feed gap sensor must be calibrated to the backing paper of
the adhesive labels. The reflective black mark sensor must be
calibrated to the darkest color of tag material on hand. The
sensors must also be aligned according to the example below.
The machine comes factory calibrated for both materials.
Make sure that the correct sensor is being used. When using notched material the
reflective black mark sensor (indicated by the arrow that is bouncing off the line)
should be used. When using adhesive backed labels the feed gap sensor (indicated
by the arrow that is passing through the line) should be used.
Make sure that when printing on notched material you change the sensor to black
mark per software setting. If the machine reads “paper jam” or “no paper”
continuously the machine might need calibration.