Technical data

Unit 6: Maintenance
S8400 Series Operator Manual
6-8 PN: 9001160 (C)
ADJUSTMENT OF HEAD POSITION
Side or Left - Right pressure balance
1.
Lock the thermal head assembly into position. Locate adjust collar, indicated by arrow in Figure 6-7.
2. Loosen the screw indicated in Figure 6-8 with Phillips screwdriver. Do not completely unscrew.
3. Rotate the adjust collar to adjust the head pressure balance.
Left hand turn Increasing head pressure on the frame side.
Right hand turn Increasing head pressure on the opposite of the frame side.
4. Tighten the screw that you previously loosened in step 2. Hold the adjust-collar when you tighten the screw.
Figure 6-7, Print Head Adjustment, Adjust Collar
Figure 6-8, Print Head Adjustment
Adjust collar
Screw