Technical data

Table Of Contents
Unit 4: Standard Command Codes
“i” Programming Reference
4-52 PN: 9001158B
PRINT MODE SELECTION
FUNCTION
To set the printing method used for a job
FORMAT
<ESC>PMa
a = 0: Continuous
1: Tear-Off
Place in separate data stream sent to the printer.
EXAMPLE
<ESC>A
<ESC>PM1
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
When the power is cycled, the value set by this command is lost and replaced by the default value
stored in the EEPROM.
To change the value stored in the EEPROM, use the Printer Setting (<ESC>PG) command or use the
Printer Setting Utility program contained on the CD-ROM shipped with the pinter.