Technical data
Table Of Contents
- 0. i Cover B
- 0. i Copyright B
- 0. i TOC B
- 1. i Introduction B
- 2. i Programming Concepts B
- 3. i Code Quick Reference B.backup
- 4. i Standard Command Codes B
- 5. i Optional Command Codes B
- 6. i Bi-Directional Communications B
- 7. i Appendix B
- 7
- appendix
- custom graphics
- CUSTOM GRAPHICS EXAMPLE
- 1. Determine the matrix size for the graphic. It must be in 8 dot by 8 dot blocks. The example here has six blocks horizontally and six blocks vertically (48 x 48).
- 2. Lay out a grid and draw the image on the grid.
- 3. Transfer the image into a bit map representation and then into hexadecimal format:
- 4. Using the hexadecimal data, send the following code to print the graphic image as designed.
- 5. To send the data in binary format, the software must convert the data into binary format before transmitting it to the printer. Using the BASIC programming language for example, this is done by notation “CHR$ (&HC0)” which sends the hexidecima...
- PCX GRAPHICS EXAMPLE
- CUSTOM GRAPHICS EXAMPLE
- printer configuration commands
- reference tables

Unit 3: Code Quick Reference
“i” Programming Reference
3-2 PN: 9001158B
COMMAND QUICK REFERENCE
INSTRUCTION DESCRIPTION
A Start Code. Begins all print jobs
A1aaaabbbb Media Size. Specifies the label size.
aaaa = Label height in dots (0 to Vmax)
bbbb = Label width in dots (0 to Hmax)
&R Form Overlay, Recall. Recalls a label image previously stored in expanded memory.
aa
= Storage number (00 to 99)
&S,aa,bbbb,cccc Form Overlay, Store. Stores a label image in Expanded Memory.
aa = Storage number (00 to 99)‘
bbbb = Horizontal size of window to be stored (50 to Hmax)
cccc = Vertical size of window to be stored (50 to Vmax)
A(space)Z Form Feed. Feeds a blank tag or label.
*a,bbb Clear Memory Card. Clears data stored on memory card.
a = Memory section to be cleared.
G: SATO graphics file (001 to 999)
F: Stored formats (001 to 999)
R: BMP graphic file (001 to 999)
bbb = Storage location to clear (001 to 999)
@,nn...n Offline/Pause. Signals the printer to go offline after upon job completion.
nn...n = Applicable only on models with an LCD. Message to be displayed
(maximum 32 characters).
A3H-aaaa-Vbbbb Base Reference Point. Establishes a new base reference point position for the current
label. Units of measurement are dots.
- = Optional character.If included, will shift reference point in negative
direction.
aaaa = Horizontal reference point
bbbb = Vertical reference point