Operator`s manual
Control Code STX (02H), ETX (03H), ACK (06H), NAK (15H)
Error Control
Method
Response Check
MB400 Quick Guide Pg 13
Adjusting the Position of the Label Sensor
1. Moving the label Sensor to the Right.
Turn the Label Sensor Adjustment Dial up.
2. Moving the Label Sensor to the Left.
Turn the Label Sensor Adjustment Dial down.
Using the Sensor
Align the right edge of the sensor with the right edge of
the label.
MB400 Quick Guide Pg 6
No. Items Details
1 Label sensor Adjust this to the label size used
2 Label sensor adjustment dial Use this to adjust the location of the
label sensor
3 Label guide Adjust this to the label size used.
4 O ring Use this ring when fixing the label
guide
5 Shoulder belt hook Attaches the shoulder belt when
hanging the printer on shoulder.
6 Adjustment screwdriver (Supplied accessory)
7 IrDA filter Location of IrDA receiving element
8 IrDA adjustment lever Changes the angle of the IrDA
receiving element.
9 Interface cover Covers the interface connector
10 Interface connector (RS232C) Connects to a computer
11 DC input jack cover Covers the DC input jack when not in
use
12 DC input jack Connects the AC adapter