Technical data

Unit 4: Configuration
SATO MB200 Operator Manual PN 9001126A Page 4-2
DIP SWITCH COMPLEX DSW1
The following tables provide guidance on the enabling/disabling of various functions and
features. This chapter deals solely with dip switch complex DSW1.
FACTORY DEFAULTS
DSW 1-1 DSW 1-2 DSW 1-3 DSW 1-4 DSW 1-5 DSW 1-6 DSW 1-7 DSW 1-8
IF Specific IF Specific IF Specific On On Off Off Off
INTERFACE CONFIGURATION
DSW 1-1 DSW 1-2 DSW 1-3 OPERATIONAL MODE
Off Off Off RS-232C
On Off Off TLL
Off On Off IrDA
On On Off Bluetooth (mode 1 using PIN code)
Off Off On RS232C, IrDA
On Off On TTL, IrDA
Off On On Bluetooth (mode 2 no authentification)
On On On Wireless LAN (802.11B)
AUTOFEED & HEAD CHECK CONFIGURATION
DSW 1-4
Off: Manual Feed or Factory Offset / On: Auto Feed or Print Darkness adjustment
DSW 1-5
Head Check - Off: Disabled / On: Enabled
MODE CONFIGURATION
DSW 1-6 DSW 1-7 DSW 1-8 OPERATIONAL MODE
Off Off Off Factory Clear Mode w/o counter clear
On Off Off Factory Clear Mode w/ head counter clear
Off On Off Factory Clear Mode w/ head counter & factory counter clear
On On Off Reserved
Off Off On Dispenser Operation
On Off On Hex Dump Mode
Off On On Font Download
On On On Program Download
NOTE: Some button/key combinations are required when altering
some dip switches. Refer to the relative mode in the Configuration
Modes chapter to follow for guidance.