Service manual

Page 2-34
Section 2. Configuration
PN 9001080
Rev. A
SATO M-8485Se Standard Print Engine
Service Manual
head Count clear
Yes no
STEP PROCEDURE
1. Use the LINE key to step the underlined cursor to the desired counter, the
Head (HD) counter or the LIFE counter. The default position is the Head
Counter.
2. Press the FEED key to display the current value (in meters) stored in the
counter.
3. Press the FEED key to advance to the next screen.
LCD Panel Printer — Counters Mode
STEP PROCEDURE
1. Press the LINE key while simultaneously turning the power on. When the
printer emits one long beep, release the LINE key to display the first
screen.
2. Press the LINE key 3X to advance to the Counters Mode.
3. Press the FEED key to advance the display to the counters selections.
The Counters Mode is provided to allow the user to access the internal printer counters
and is entered from the Advanced Mode.
ADVANCED MODE
To Enter Advanced Mode:
counters mode
The counters are identified in the display as:
HD: Head Counter (should be reset when print head is replaced)
DSP: Dispense Counter
CUT: Cutter Counter
LIFE: Life Counter (cannot be reset)
Counters
hd dsp cut life
Counters
HD DSP CUT LIFE
head counter
xxxxx m