Service manual

Page 2-6
Section 2. Configuration
PN 9001080
Rev. A
SATO M-8485Se Standard Print Engine
Service Manual
Dip Switch Settings
DSW3
ON
OFF
1 2 3 4
5 6 7 8
DSW3-6 DSW3-7 SETTING
Off Off Type 4
Off On Type 3
On Off Type 2
On On Type 1
DSW3
ON
OFF
1 2 3 4
5 6 7 8
DSW3-8 SETTING
Off Disabled
On Enabled
External Signal Type Selection (DSW3-6, DSW3-7): Both the polarity and signal
type (level or pulse) of the external print synchronizing signal can be selected. See
Section 3: Interface Specifications for a definition of signal types.
Repeat Print via External Signal (DSW3-8): Allows the applicator to reprint the
last label of the print job. See Section 3: Interface Specifications for a description of
the signal requirements.