Installation guide
A P P E N D I X B
B-2
1.1.2 CONFIGURE THE PLUG
1. If the power supply cord is not provided with an attachment plug cap, configure a new plug to the
power supply cord in accordance with following procedures.
2. Prepare a plug that has appropriate rating and agency approval as shown in the table below and
proceed as follows:
Plug Type Reference
Standards
250V AC
25A
CEE 7-7
UK
240V AC
30A or more
(INDUSTRIAL)
BS 4343
IEC 309-2
EN 60309-2
CEE 17
3. Configure the Power Supply Cord as follows:
Strip the Power Supply Cord.
Strip the wires as appropriate for the terminal of plug used.
4. Install a new plug to a power supply cord using the correct color configuration.
The wire that is colored GREEN/YELLOW must be connected to the terminal in the plug which could be
marked by the letter E or PE or by the earth symbol or colored GREEN or GREEN/YELLOW.
The wire that is colored BLUE must be connected to the terminal in the printer that is marked with the
letter N or colored BLACK.
The wire that is colored BROWN must be connected to the terminal in the printer that is marked with
the letter L or W or colored RED.
1.1.3 CONFIRM THE GROUND
Please reconfirm that the grounding conductor in the supply cord is connected between the terminal
in the printer that is marked with the letter FG and the terminal in the plug which could be marked with
the letter E or PE or by the earth symbol or colored GREEN or GREEN/YELLOW.
WARNING
THIS APPARATUS MUST BE PROPERLY GROUNDED.