Installation guide
A P P E N D I X B
B-1
+20
-10
+20
-10
EUROPEAN POWER CONSIDERATIONS
1.1 POWER CORD INSTRUCTIONS (EUROPE)
DANGER
THIS APPARATUS IS SHIPPED WITH THE POWER SUPPLY
CORD AND THE PLUG WHICH IS CERTIFIED FOR USA AND
CANADA. IF IT IS USED IN EUROPEAN COUNTRIES, THE
POWER SUPPLY CORD AND PLUG SHOULD BE CHANGED
BY THE LAW AS FOLLOWING.
1.1.1 REPLACING THE POWER SUPPLY CORD
1. Remove the factory installed power supply cord.
2. To configure a new power supply cord, the following hardware and tools should be used.
The power supply cords for European Countries should meet the following standards:
(1) Should use three conductor wire whose nominal cross-sectional area is 2.5 mm or more
each.
(2) Should be at 3000 mm long.
(3) Should have '<HAR>' marking.
The terminals should be ring type, appropriate for 6 mm screw and wire as described above,
having approval from VDE, TUV or other agencies.
Crimping tools for the terminals should be used in accordance with instructions by the
manufacturer of the terminals.
Rating Voltage Length Cross-section Area Marking
Power Supply Cord min 240V 3000 mm min 2.5 mm
2
x3 <HAR>
3. Process the Power Supply Cord as follows.
Strip the Power Supply Cord in length of 40 mm
Cut the BLUE and BROWN wires 10mm shorter than the wire colored GREEN/YELLOW.
Strip the wires the appropriate length for the terminals to be used. Clamp the terminals on the
wire using a tool in accordance with the instruction by the manufacturer of the terminal.
4. Install a new power supply cord to the Printer in accordance with following procedures.
The wire that is colored GREEN/YELLOW must be connected to the terminal in the printer that
is marked with the letter FG.
The wire that is colored BLUE must be connected to the terminal in the printer that is marked with
the letter N.
The wire that is colored Brown must be connected to the terminal in the printer that is marked with
the letter L.
10
B R
B L
G / Y