Instruction manual

Section 3: Operation and Configuration
GY412 Operator Manual Page 3-69
3.3 LCD MESSAGE DETAILS (cont’d)
Display Advanced Mode - Head check method setting
Onscreen
message
Setting the head check range.
Use and keys to move the cursor and press
ENTER.
"LAST ITEM" : Performs head check when paus-
ing the print operation in Continuous Mode or
when in back feed motion.
"CHECK PAGE" : Performs head check based on
the count specified in [HEAD CHECK PAGE
NO.].
"ALL CHECK" : Performs head check per label.
The default setting is “LAST ITEM”.
This message is displayed only when [HEAD
CHECK] is set to “ENABLE”.
Operation
button
Button Description
↓↑ Moves the cursor.
ENTER "ALL CHECK": Saves the setting and goes to the
[SELECT LANGUAGE] screen.
"LAST ITEM": Saves the setting and goes to the
[SELECT LANGUAGE] screen.
"CHECK PAGE": Saves the setting and goes to
the [HEAD CHECK PAGE NO.] screen.
CANCEL Goes to the [HEAD CHECK] screen without sav-
ing the setting.
FUNCTION Goes to the [ONLINE MODE] screen without sav-
ing the setting.
HEAD CHECK MODE
ALL CHECK
CHECK PAGE
LAST ITEM