Instruction manual
Section 3: Operation and Configuration
Page 3-50 GY412 Operator Manual
3.3 LCD MESSAGE DETAILS (cont’d)
Display Interface Mode - Status reply timing setting
Onscreen
message
Setting the timing to return the status information
to the host computer.
Use ← and → keys to move the cursor and press
ENTER.
"ENQ" : Returns the printer status by receiving
the status request (ENQ) from the host computer.
"CYCLE" : The printer returns the printer status to
the host computer at intervals of 500ms.
The default setting is "ENQ".
This screen is displayed only when “STATUS4” is
selected in [PROTOCOL].
Operation
button
Button Description
←, → Moves the cursor.
ENTER Saves the setting and goes to the [ONLINE
MODE] screen.
CANCEL Goes to the [PORT NUMBER3] screen without
saving the setting.
FUNCTION Goes to the [ONLINE MODE] screen without sav-
ing the setting.
STATUS REPLY TIMING
ENQ CYCLE