Instruction manual

Section 3: Operation and Configuration
Page 3-46 GY412 Operator Manual
3.3 LCD MESSAGE DETAILS (cont’d)
Display Interface Mode - LAN port number 1 setting
Onscreen
message
Setting LAN port number 1.
Use and keys to change setting value and
press ENTER.
Use and keys to move the cursor to an input
item.
The default setting is "01024".
Setting range is from "00000" to "65535".
[Important] Changed setting becomes effective at
next power-on.
Note: You cannot assign the number currently
used in "PORT NUMBER2” and “PORT
NUMBER3”.
Operation
button
Button Description
, Enters setting value.
, Moves the cursor.
ENTER Saves the setting and goes to the [PORT
NUMBER2] screen.
CANCEL If “MANUAL” is selected in [IP RESOLUTION
METHOD], it goes to the [GATEWAY ADDRESS]
screen without saving the setting.
If “DHCP” is selected in [IP RESOLUTION
METHOD], it goes to the [IP RESOLUTION
METHOD] screen without saving the setting.
FUNCTION Goes to the [ONLINE MODE] screen without sav-
ing the setting.
PORT NUMBER1
01024