Instruction manual

Section 6: Basic Specifications
GY412 Operator Manual Page 6-1
6
GENERAL SPECIFICATIONS
6.1 PRINTER BASIC SPECIFICATIONS
MODEL NAME
GY412
PHYSICAL CHARACTERISTICS
Width 8.39 in. (213 mm)
Height 11.06 in. (281 mm)
Depth 11.93 in. (303 mm)
The below dimensions apply when you open or
close the cover
Width 8.39 in. (213 mm)
Height 18.07 in. (459 mm)
Depth 12.09 in. (307 mm)
Weight approximately 26.46 lbs. (12 Kg)
ENVIRONMENTAL (EXCLUDING MEDIA)
Operating Temperature 32 to 104°F (0 to 40ºC) Not considering consumables
Storage Temperature (-5 to 60ºC) Not considering consumables
Operating Humidity 30 to 80% RH, Non-condensing
Storage Humidity 30 to 90% RH, Non-condensing
POWER SPECIFICATIONS
Input Voltage
Input power voltage: AC100 to 240V±10%
Rated voltage: AC100V/AC240V
Power Consumption
Input voltage requirement: 100V/50Hz
At peak: 144W/144VA
During standby: 11W/13VA
Low-power consumption
function
Power saving mode: LCD backlight turns off when the key is not pressed, the cover
is not opened/closed or the data is not received for a certain period of time.
(Set the time by minutes in the range of 0 to 15 minutes)