Instruction manual

Section 3: Operation and Configuration
Page 3-86 GY412 Operator Manual
3.3 LCD MESSAGE DETAILS (cont’d)
Display Service Mode - Slice level of I-mark sensor
Onscreen
message
Displaying current I-mark sensor level and auto-
matically calculated slice level.
Use and keys to enter slice level and press
ENTER.
The setting range is from 0.0 to 3.2, set by 0.1V.
Firmware will set the slice level automatically if
setting the slice level to “0.0”.
Operation
button
Button Description
, Enters slice level value by 0.1.
ENTER Saves the setting and goes to the [SENSOR
LEVEL GAP1] screen.
CANCEL Goes to the [SERVICE MODE] screen without
saving the setting.
FUNCTION Goes to the [SERVICE MODE] screen without
saving the setting.
Display Service Mode - Slice level of Gap1 sensor
Onscreen
message
Displaying current GAP1 (center hole) sensor
level and automatically calculated slice level.
Use and keys to enter slice level and press
ENTER.
The setting range is from 0.0 to 3.2, set by 0.1V.
Firmware will set the slice level automatically if
setting the slice level to “0.0”.
Operation
button
Button Description
, Enters slice level value by 0.1.
ENTER Saves the setting and goes to the [SERVICE
MODE] screen.
CANCEL Goes to the [SENSOR LEVEL I-MARK] screen
without saving the setting.
FUNCTION Goes to the [SERVICE MODE] screen without
saving the setting.
0.0V
SENSOR LEVEL
I-MARK SLICE LEVEL
0.0V
SENSOR LEVEL
GAP1 SLICE LEVEL