Specifications
Table Of Contents

Operation Manual 2. Configuration
DR300 19
Size Check (DSW2-7)
Controls the length of the loaded media to the size installed by soft-
ware.
Demand Mode (DSW2-8)
Enables the Tear-Off function for Dispenser use.
Reserved for Future Use (DSW3-1 - DSW3-6)
Selecting Protocol Control Codes (DSW3-7)
Selects the command codes used for protocol control.
Selecting Protocol Control Codes
Protocol control codes are the special control characters that pre-
pare the printer to receive instructions. For example, the <ESC>
character tells the printer that a command code will follow and the
<ENQ> character asks for the printer status.
There are two pre-defined sets of Protocol Control codes to choose
from. Each set is made up of six special characters. The
Standard
Protocol Control
codes are non-printable characters, and the
Non-Standard Protocol Control
codes are printable characters.
The Non-Standard set may be useful on host computers using pro-
tocol converters or in an application where non-printable ASCII
DSW2-7 SETTING
OFF Disabled
ON Enabled
12 345678
ON
OFF
DSW2
DSW2-8 SETTING
OFF Disabled
ON Enabled
12 3 4 5 6 78
ON
OFF
DSW2
DSW3-1 Setting
OFF Standard
ON Non-Standard
12 345678
ON
OFF
DSW3