Specifications

Operation Manual 3. Configuration
CL608e/612e 19
Back Feed Selection (DSW3-4)
When Back-Feed is enabled, the printer will position the label for
dispensing/cutting and retract it to the correct print position before
printing the next label.
Note: Back Feed function only works, if Tear Off, Cutter or
Dispenser is selected. See DSW3-1, 3-2.
External Signal Interface
The EXT connector on the CL printer rear panel is intended for use
with the external printer accessories such as label rewinders or
applicators. The 14-pin Centronics type connector provides a
choice of four different output signals along with various error con-
ditions.
Print Start Signal Selection (DSW3-5)
External Signal Type Selection (DSW3-6, DSW3-7)
Both the polarity and signal type (level or pulse) of the external print
synchronizing signal can be selected.
* Factory Default
DSW3-4 SETTING
*
OFF
Enabled
ON Disabled
12 345678
ON
OFF
DSW3
DSW3-5
SETTING
*OFF
Disabled
ON Enabled
(Output on Pin 5)
12 3 4 5 6 7 8
ON
OFF
DSW3
1 2 3 4 5 6 7
8
ON
OFF
DSW3-6 DSW3-7 SETTING
*Off
*Off
Type 4
Off
On
Type 3
On Off Type 2
On
On
Type 1
(Output on Pin 6)
DSW3