User's Manual

21-Sep-10 49-70-020-DOC 5
User Manual
MSTRP Tunnel Readers
About tHis mAnuAl
Please read this document before using Magellans readers.
This manual is designed for use by engineers experienced with Radio Frequency Identication (RFID) devices. Regulatory, safety and
warranty notices that must be followed are given in chapter 6.3 and 6.6.
meAning of AleRt symbols And signAl WoRds
Notes and Tips. Application Notes.
Requires your attention.
Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may
result in serious injury or death. Can cause signicant property damage.
impoRtAnt infoRmAtion
Installation Environment
For indoor use only unless otherwise specied.
Install Magellans readers within the temperature and humidity range according to the product specication. For
standard readers the temperature range is from +10°C to +45°C. The humidity range is from 10% to 80% (non-
condensing humidity).
The environment must not contain corrosive, ammable or explosive agents or be subject to rapid changes in
temperature, to direct vibration or shock.
Installation
Magellan’s RFID reader-writers communicate with data carriers (RFID inlets, labels and tags) using the 13.56 MHz
High Frequency (HF) band. Some industrial machines and electronic devices can generate unwanted noise which
may degrade communication. Make sure that other equipment is properly installed, grounded and at a reasonable
distance from the reader and/or reader antennas.
Wireless communication can be degraded by high-voltage and high-current lines and other sources of strong
electric and magnetic elds. Installation in such locations should be avoided.