User's Manual

21-Sep-10 49-70-020-DOC 27
User Manual
MSTRP Tunnel Readers
5.2 HoW to CHeCk A tAg ConfiguRAtion mode
The tag conguration mode can be checked with the ReaderManager:
Go to Tools -> System -> Interrogate Command.
In Reply select Normal and click Send.
Then go to Tools -> System -> Table of Tag Messages to see the tag conguration in the Cong column. The
messages of all the tags currently in the reader antenna eld can be seen. 2000 or 3000 means that the tag has been
recongured to ST ¼ normal power mode conguration. 6000 means that a tag is in ST normal power mode.
5.3 HoW to CHeCk A tAg CHip type (it oR st)
The tag chip type can be checked with the ReaderManager:
Go to Tools > System > Tag Memory Map
Place a tag on the antenna. The tag ID# will appear below “Current tags
Left mouse click on the ID#
The chip type can be seen in the Value column of the System Memory in line “0”:
Value for ItemTag chip is XXX0
Value for StackTag chip is XXX1
Note X means do not care”
5.4 tAg-to-AntennA oRientAtion
The MSTRP-5050 and MSTRP-6464 are three axis tunnel readers which generate a rotating eld in x-, y- and z-orientation.
Tags will operate in all orientations and positions inside the internal operating volume. With StackTags, multiple closely
stacked tags can be presented in all orientations.
The internal operating volume starts 20-cm inside from both ends of the reader tunnel.
The smallest ST tags that can work with the reader are the 35 mm diameter and 26 x 56 mm (Refer to the Tag Reference
Table on our website).
1.
2.
3.
4.