User's Manual
26 49-70-020-DOC 21-Sep-10
User Manual
MSTRP Tunnel Readers
5. WORKING WITH TAGS
Do not stack Magellan ItemTags on top of each other or allow them to touch or overlap. Only Magellan StackTags can
be stacked, overlapped or allowed to touch each other.
Single-axis antennas are tag orientation sensitive. Refer to the Tag-to-Antenna section of this document.
Reading and writing speeds depend on reader-tag communication speeds, the number of receiver channels, the
amount of information to be read and/or written and the number of tags presented at a the same time. The number
of tags and the amount of information to be read and especially written, slows down the read-write communication
speed. Please consult Magellan regarding these issues for your specic application.
Be aware that tags and readers can be incompatible with each other. For example smaller tags require higher eld
strengths and as a result they may not operate with some reader/antenna combinations or have to be closer to a
reader antenna to operate. Refer to the Reader-Tag Compatibility section of this manual.
Magellan StackTags are congured to normal powered mode at manufacture. This mode is required for tag
manufacture.
To allow for stacking, tags must be congured to quarter power mode. This mode is essential for providing the correct
conditions required to reliably identify stacked tags. This conguration can be done as part of the tag issuing process
and if not done earlier in the delivery process must be done by the end-user.
Tags can be recongured individually (one by one) or en masse (many at once). Before reconguring tags make sure the
ReaderManager software has been installed and upgraded to the latest version, the reader is running and the reader is
Connected to the ReaderManager software.
5.1 HoW to ReConfiguRe tAgs individuAlly oR en mAsse
In the ReaderManager go to Tools -> System -> Console. Click with the right mouse button and tick Show
Tag Replies.
For ReaderManager version 2.38 or higher go to Reader Conguration and choose Cong_Normal_
Powered_Tag or Cong_Quarter_Powered_Tag . Alternatively and for earlier ReaderManager versions
copy the following in the lower Console window:
Actions(Command(command=CommandNormalReply,readAddress=6,readLength=1,writeAddress=6,
writeData=[0x3000,]))
and then press enter. With write data=[0x3000,] tags will be congured to quarter power mode and with
write data=[0x6000,] tags will be congured to normal powered mode.
Place a single tag or multiple tags into the reader antenna eld.
Remove the tag(s) from the eld.
Follow the step 3 to 4 for a new batch of tags.
Once completed go to Reader Conguration and click on Clear All.
1.
2.
3.
4.
5.
6.