User's Manual
30 49-70-020-DOC 13-Nov-0749-70-020-DOC 13-Nov-07 13-Nov-07
User Manual
MSTRP-5050 (MC 5/6)
5.2 HoW to CHeCk A tAg ConfiguRAtion mode
The tag conguration mode can be checked with the ReaderManager:
Go to Tools -> System -> Interrogate Command.
In Reply select Normal and click Send.
Then go to Tools -> System -> Table of Tag Messages to see the tag conguration in the Cong column.
The messages of all the tags currently in the reader antenna eld can be seen. 2000 means that the tag has
been recongured to ST ¼ normal power mode conguration. 6000 means that a tag is in ST normal power
mode.
5.3 HoW to CHeCk A tAg CHip type (it oR st)
The tag chip type can be checked with the ReaderManager:
Go to Tools > System > Tag Memory Map
Place a tag on the antenna. The tag ID# will appear below “Current tags”
Left mouse click on the ID#
The chip type can be seen in the “Value” column of the System Memory in line “0”:
4000 means ItemTag chip
4001 means StackTag chip
5.4 tAg-to-AntennA oRientAtion
The MSTRP-5050 is a three axis tunnel reader which generates a rotating eld in x-, y- and z-orientation. Tags
will operate in all orientation and positions inside the internal operating volume. With StackTags, multiple closely
stacked tags can be presented in all orientations.
The internal operating volume starts 20-cm inside from both ends of the reader tunnel.
The smallest ST tags that can work with the reader are the 35 mm diameter and 26 x 56 mm (Refer to the
Reader-Tag Compatibility Appendix of this Manual).
•
•
•
1.
2.
3.
4.