Reader Manager Guide Page 33 of 62 40-10-006-DOC 15/09/2006
Select
Tools->System->Reader setup
Tick Use Wizard
Click Go
Select
Load settings from the Reader.
Click
Load Settings
Acknowledge setting have been
loaded
Click OK
Click
Edit groups
Ensure only one
group is shown.
Click
Configure groups
This setup flow chart makes the following assumptions:
1. The settings in the reader are set to the factory default.
2. Only one axis group is required.
3. ReaderManager is connected to the reader.
Before starting the setup procedure ensure you have the following:
1. DC voltmeter able to measure 100mV to 12V.
2. Tuning block.
3. Trim tool.
4. A stack tag set to Normal Powered Mode
Ensure
Independent Axes is ticked.
Toggle Reader ID is ticked.
Group Priority is 1.
Tag Reply Mode is set to
the readers default setting.
From the Antenna Type list select
the antenna which is connected to
the Axis port shown at the top of
the form.
Click Next to setup the next Axis.
Is this the last
axis?
Click
Save Configuration
Click
Configure axis
Click
Save to Reader
Click
Tune Axis
Follow the tuning instructions
displayed on the form
Move the tuning block to the next
antenna.
Click Next to setup the next Axis.
Is this the last
axis?
Click
Test axis
Place a Normal powered stack tag
on the antenna.
Click Start
Is this the last
axis?
Click
Display summary
Move the tag to the next antenna
Click Next to setup the next Axis.
Does the test
PASS
Consult the trouble shooting
section in the your Reader's user
guide and in the antenna tuning
guide.
End
Save the settings to the reader by
clicking Yes
N
Y
N
Y
N
Y
N
Y
Acknowledge setting have been
saved
Click OK
Figure 22