User Guide
Reader Manager Guide Page 28 of 62 40-10-006-DOC 15/09/2006
Index
Description / Command Index Description / Command
6
ToggleReaderID()
Tick this enable the reader to change
the Reader ID periodically.
25
AxisPeriod()
1
Sets the number of milliseconds to spend on an axis.
7
TimeStamp()
Change the TimeStamp sent to the
reader.
26
AxisOffPeriod()
Sets the minimum number of milliseconds to switch
the power off between axes.
8
InterrogateBreak()
1
Set the number of small power breaks
to send to the reader when operating in
stack mode.
27
AxisCount()
Use this drop down list to select the number of axes
used by the reader.
9
UnmuteCount()
Set the number Interrogate Commands
per break to unmute tags during the
unmute phase of an ID cycle.
28
IDCycleExpiryCount()
Sets the number of axis ID cycles to wait before
expiring a tag.
10
ReaderID()
Change the ReaderID sent to the reader
in an interrogate command. Only valid
when Toggle Reader ID is disabled.
29
TagTimeout()
1
Set the number of milliseconds to wait before timing
out the tag.
11
TimeStampScalingFactor()
Set the rate at which the timestamp
field of the command number in the
interrogation command changes.
30
CurrentAxis() and AxisLabels()
To change the current axis:
1. Uncheck the Switching checkbox (35)
2. Select the axis you would like to power
using the drop down list.
To change the axis name:
1. Select the axis you would like to rename
from the dropdown list
2. Delete the current name and enter the new
axis name.
3. Press enter when done.
12
InterrogateCount()
Sets the number of interrogate
commands sent per break. The sliding
check box should be left ticked.
31
AxisMinPeriod()
Set the minimum number of milliseconds to spend
on an antenna. Settings this parameter to zero means
operate at the fastest possible speed.
13
BreakCount()
Sets how many small power breaks are
sent when the reader is operating in
stack tag mode.
32
AxisMaxPeriod()
Set the maximum number of milliseconds to spend
on an antenna. Settings this parameter to zero means
operate with no maximum.
14
DefaultReplyActions()
If ticked sets default actions for post
scripts.
33
NoReplyAxisCount()
1
Sets the number of axis periods with no replies
before performing the necessary actions.
15
FullReplyFormat()
If ticked the reply includes extra
information related to the tags
configuration and reply channel.
34
AxisColdPowerUp()
Not used
16
ShowHardCode()
If ticked tag replies will include the
tags HardCode value.
35
Switching()
If ticked will enable axis switching.