Operation Manual
Manual Indicator SA 250
pag. 12
PCG/C SA 250 Indicator Manual 23-03-07
The User Mode is selected by pressing key continuously and then
starting the scale with key .
As soon as the display shows: CAL , release the key.
Press key to step to the first and the next menu lines.
After operating key in one of the menu lines, the present values of that
line will be entered, followed by automatic stepping to the next line.
Use key to edit a parameter in a menu line
The menu may be closed with key , all (edited) data will be memorized
that have been entered with key
However: once an weight adjusting procedure has been started, it has to be
completed to its full extend. If this is not done, the weighing results will be
incorrect and not reliable.
The User mode is not accessible in legal stamped scales.
Attention !
The calibration mode in legal stamped scales is under EC rules not accessible. The breaking of the legal seals only
makes this access possible. Breaking the seals of housing and platform terminates the warranty, besides that it is a
legal crime that may cause severe financial fines.
18 different scale divisions (d) are selectable:
0.001 0.1 0.010
0.002 0.2 0.020
0.005 0.5 0.050
0.01 1 10
0.02 2 20
0.05 5 50
With key the available choices are shown.
With key the selected choice may be entered , followed by automatic
stepping to the next menu line.
If the scale has to be adjusted only, skip this function by pressing key .
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
Scale divisions
CALIBRATION mode how to operate
MENU CALIBRATON mode (not accessible in legal stamped scales and on request)
The hatched frames
show the default
settings.