Operation Manual
Manual Indicator SA 250
pag. 10
PCG/C SA 250 Indicator Manual 23-03-07
Four different functions of the RS 232 data output are available:
0 = switched off
1 = 1 x transmission after key operation at standstill
2 = automatic 1 x transmission each time the scales comes to a standstill
after return to zero and standstill at zero and the display reading is
not at zero
3 = continuous transmission with ca. 10 Hz
Choices 2 and 3 are not available for the counting and lock up modes.
With key the available choices are shown.
With key the selected function may be entered , followed by automatic
stepping to the next menu line.
Twice printing of the same weighing could be undesirable and may be
switched off disabled by setting the condition that a second printing is allowed only if the
reading has been returned one time to 0 kg.
+/- 1 d This “0 value” may be setted at + and - 1, 2 or 5 scale divisions (d)
around the actual zero.
At setting at 0, double printing / data transmission is not disabled.
+/- 2 d
With key the available choices are shown.
+/- 5 d With key the selected function may be entered , followed by automatic
stepping to the next menu line.
In order to place the printed lines on a printed label on the required hight, max.
9 empty lines may be inserted in front of
the actual data lines.
The shown number corresponds with the number of empty lines (line feeds).
With key the available numbers are shown.
With key the selected number may be entered , followed by automatic
stepping to the next menu line.
In order to create more space after the printed lines, 9 empty lines may be
inserted after
the actual data lines.
The shown number corresponds with the number of empty lines (line feeds).
With key the available numbers are shown.
With key the selected number may be entered , followed by automatic
stepping to the next menu line.
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
Printer / RS 232 data output
Extra empty lines (Line Feeds - For)
Extra empty lines (Line Feeds - After)
Disable double printing (added medio 2007)