Operation Manual
pag. 9
PCG/C SA 250 Indicator Manual 23-03-07
The back lightning of the display may be selected as:
0 = always off
1 = always on
2 = automatically switching on if weight > 0,0 kg
With key the available choices are shown.
With key the selected function may be entered , followed by automatic
stepping to the next menu line.
After switching on the scale will automatically:
0 = set zero based upon the last time the scale was set to zero with
1 = set zero based upon the actual situation, after standstill
With key the available choices are shown.
With key the selected function may be entered , followed by automatic
stepping to the next menu line.
The speed of refreshment of the display reading is settable. Under unstable
conditions a lower refreshment speed may give better readability of the weight
values.
0 = standard, 10 Hz
1 = low speed, 5 Hz.
2 = lowest speed 2 Hz.
With key the available choices are shown.
With key the selected function may be entered , followed by automatic
stepping to the next menu line.
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
Manual Indicator SA 250
Back light display
Initial zero setting
Display speed