User manual
Table Of Contents
- 1. General
- 2. Technical reliability of the alarm system
- 3. Alarm system operating costs
- 4. Authorization of users
- 5. Operating the alarm system by means of LCD keypad
- 5.1 Keypads description
- 5.2 [Code] – arming / disarming menu
- 5.3 [Code] – user menu
- 5.4 Arming
- 5.5 Disarming and alarm clearing
- 5.6 Two-code arming / disarming
- 5.7 Triggering the alarm from keypad
- 5.8 Users
- 5.9 Master users (administrators)
- 5.10 Zone bypassing
- 5.11 Viewing the event log
- 5.12 Programming the partition timer
- 5.13 Zone testing
- 5.14 Outputs control
- 6. Using the partition keypad
- 7. Using the entry keypad
- 8. Using the code lock
- 9. Confirming voice messaging
- 10. Call answering and telephone control
- 11. Operating the alarm system by means of keyfob
- 12. Manual update history
- 13. Brief description of operating the system from keypad

SATEL INTEGRA Plus 37
6.1.4 Sound signaling
Beeps generated when operating
The installer can disable the sound signaling or replace it with blinking of the keys
backlight.
1 short beep – pressing any digit key, confirmation that code has been entered or card has
been read.
2 short beeps – acceptance of the first code during two code arming / disarming.
3 short beeps – signaling of:
– starting the procedure of arming (if no exit delay time has been programmed for the
partition, this is equivalent to arming),
– disarming and/or alarm clearing.
4 short and 1 long beeps – confirmation that the function has been executed.
3 pairs of short beeps – the user should change his/her code.
1 long beep – refusal to arm (there are violated zones in the partition or there is a trouble).
2 long beeps – unknown code/card.
3 long beeps – unavailable function.
Events signaled by sounds
Only installer selected events are signaled.
Alarms are signaled for the time programmed by the installer.
5 short beeps – zone violation (CHIME).
Long beep every 3 seconds, followed by a series of short beeps for 10 seconds
and 1 long beep – countdown of exit delay (if the time is shorter than 10 seconds, only
the final sequence of short beeps will be generated).
A sequence of 7 beeps of diminishing duration, repeated every few seconds –
countdown of auto-arming delay.
2 short beeps every second – countdown of entry delay.
Continuous beep – alarm.
Long beeps every 2 seconds – alarm memory.
Long beep every second – fire alarm.
Short beeps every 2 seconds – fire alarm memory.
Very short beeps – door open too long.
6.2 Functions available from the partition keypad
6.2.1 [Code]
Depending on the user type and authority level, keypad settings and the alarm system status,
entering the code and confirming with the
key will result in:
– unlocking the door (activating the relay);
– disarming the partition;
– clearing alarm;
– changing over the status of 25. BI
SWITCH type outputs;
– turning on the 24. MONO
SWITCH type outputs;