Ethernet communication module ETHM-1 Plus Firmware version 2.00 ethm1_plus_en 07/14 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.
WARNINGS The module should be installed by qualified personnel. Read carefully this manual before proceeding to installation. Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty. FreeRTOS is used in this device (www.freertos.org). The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical specifications and firmware.
1 2 3 4 5 6 7 8 CONTENTS General............................................................................................................................. 2 Field of application............................................................................................................ 2 Electronics Board..............................................................................................................3 Setting address..........................................................................
2 ETHM-1 Plus SATEL 1 General The ETHM-1 Plus module enables the INTEGRA Plus, INTEGRA and VERSA alarm control panels to communicate via the Ethernet network. The data transmission is encrypted by means of an advanced algorithm based on 192-bit key. The module firmware can be updated using the application available on www.satel.eu 2 Field of application Control panel configuration using the DLOADX program from a computer with Internet access.
SATEL ETHM-1 Plus 3 3 Electronics Board Fig. 1. Module electronics board. terminals: +12V COM TMP A RS485 B DTM CKM - +12 V DC power input. common ground. tamper input (NC) – if not used, it should be shorted to common ground. terminals provided for future applications (RS-485). data (communication bus). clock (communication bus). RS-232 port. PWR/LOG LED: OK – power OK, blinking – control panel being programmed or operated by means of the module.
4 ETHM-1 Plus Address Pins status 0 1 2 SATEL 3 4 5 6 7 Table 1. 4.1 Module connected to INTEGRA / INTEGRA Plus control panel Set an address in the module within the range: from 0 to 3, if it is connected to INTEGRA 24 or INTEGRA 32 control panel, from 0 to 7, if it is connected to another INTEGRA or INTEGRA Plus control panel.
SATEL ETHM-1 Plus 5 4. If the module is to supervise the enclosure tamper switch, connect the tamper switch wires to the TMP and COM terminals. Otherwise, connect the TMP terminal to the module COM terminal. 5. Connect the module to the Ethernet network. Use a cable compliant with the 100Base-TX standard (identical as for connecting the computer to the network). 6. Power on the alarm system. 7. Start the identification function in the control panel (see the control panel installer manual).
6 ETHM-1 Plus SATEL 6 Configuring The module can be configured via the control panel, using a keypad or a computer with DLOADX program installed on it. 6.1 Module parameters and options 6.1.1 Module connected to INTEGRA / INTEGRA Plus control panel You can configure parameters and options of the module using: LCD keypad: SERVICE MODE STRUCTURE HARDWARE LCD KEYPADS SETTINGS [module name], DLOADX program: "Structure" window "Hardware" tab "Keypads" branch [module name] "ETHM-1" tab (Fig.
SATEL ETHM-1 Plus 7 In the LCD keypad, the function for programming address of the computer with DLOADX program is available in the user menu, CHANGE OPTIONS submenu (available to service and administrators). Fig. 5. DLOADX program: parameters and options of ETHM-1 Plus module connected to INTEGRA / INTEGRA Plus control panel. GuardX / Java GuardX [Connect GuardX] – if this option is enabled, it is possible to initiate connection with the control panel via Ethernet from the GUARDX program.
8 ETHM-1 Plus SATEL WWW [Connect Intern.] – if this option is enabled, it is possible to initiate connection with the control panel via Ethernet from the web browser. GSM [Connect GSM] – if this option is enabled, connection with the control panel via Ethernet can be initiated from the MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO application.
SATEL ETHM-1 Plus 9 Port [Port (integr.)] – number of the TCP port used for integration. You can enter values from 1 do 65535. The value must be different from that entered for the other ports. Default value: 7094. Wrong login Log event [Fail. – event] – if this option is enabled, all unauthorized attempts to connect to the module are written to the event log. Alarm [Fail. – alarm] – if this option is enabled, any unauthorized attempt to connect to the module will trigger the tamper alarm.
10 ETHM-1 Plus SATEL Port [DloadX port] – number of the TCP port used for communication with the DLOADX program. You can enter values from 1 to 65535. The value must be different from that entered for the other ports. Default value: 7090. DLOADX server [DloadX] – address of the computer running the DLOADX program. If the computer is not in the same local network, it must be a public address. You can enter either the IP address or the domain name.
SATEL ETHM-1 Plus 11 6.2 Virtual keypad The virtual keypad allows you to operate and program the alarm system in much the same way as using a physical keypad. 6.2.1 Module connected to INTEGRA / INTEGRA Plus control panel You can use the virtual keypad in the DLOADX and GUARDX programs, web browser and in the mobile phone (after installation of the MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO application). Fig. 7.
12 ETHM-1 Plus SATEL DLOADX program: ”Structure” window ”Hardware” tab ”Keypads” branch ”DloadX (RS-232)” item. Settings of the virtual keypad available in the GUARDX program, web browser or mobile phone can be programmed using: LCD keypad: SERVICE MODE STRUCTURE HARDWARE LCD KEYPADS SETTINGS GUARDX ADDR. n [n = module address], DLOADX program: ”Structure” window ”Hardware” tab ”Keypads” branch [module name] branch ”GuardX/MobileKPD” item (Fig. 7).
SATEL ETHM-1 Plus 13 ("Structure" window "Hardware" tab "Keypads" branch [module name] branch "GuardX/MobileKPD" item "Macro Commands" tab). Defined macro commands will be automatically downloaded by the MOBILEKPD-2 PRO application after establishing connection with the ETHM-1 Plus module. Macro commands can be loaded into the application without establishing connection with the module.
14 ETHM-1 Plus SATEL Name – name of the macro command group (up to 8 characters). It is presented on the macro key. Add macro – button available after you click on a macro command group. Clicking on the button will display a list of defined macro commands. Click on the name to add the macro command to the group. Remove macro – click on the button to delete the selected macro command from the group. – click on the button to move the highlighted macro command down within the group.
SATEL ETHM-1 Plus 15 Change – click on the button to save the changes to the command parameters which were made after adding the command to the list (otherwise, the changes made will not be saved). Delete – click on the button to remove the highlighted command from the list. Fig. 10. DLOADX program: "Definitions" tab. Command – function executed by the control panel, which can be assigned to the macro command. To display the list of all available functions, click on the button.
16 ETHM-1 Plus SATEL Outputs ON – highlight the outputs which are to be activated (double-click on the field designated by the output number). Outputs OFF – highlight the outputs which are to be deactivated (double-click on the field designated by the output number). Change outputs state – highlight the outputs whose status is to be changed (double-click on the field designated by the output number).
SATEL ETHM-1 Plus 17 3. Click on the "New macro" button. A new macro command will appear on the list. 4. Enter a name for the new macro command. 5. If the macro command is to be run without entering the code by the user, enter a code having appropriate authority level. 6. If running a macro command is to be each time preceded by user authorization, enable the AUTHORIZATION REQUIRED option. 7.
18 ETHM-1 Plus SATEL 8. If the macro command is to be run immediately on tapping the macro key, enable the AUTOEXECUTE option (in such a case, only this one macro command is to be assigned to the group). 9. Click on the button and select the function the new macro command is to execute. 10. Configure the command parameters.
SATEL ETHM-1 Plus 19 11. Click on the "Add" button. A new command will appear on the list of commands assigned to the macro command. You can still modify parameters of the command after clicking on it (having made the changes, click on the "Change" button). 12. Repeat the steps 9-11, if you want to add next commands. 13. Click on the "Groups" tab. 14. Click on the group you want to edit. 15. Enter the group name.
20 ETHM-1 Plus SATEL 16. Click on the "Add macro" button. A list of all defined macro commands will be displayed. 17. Click on a macro command to add it to the group. The macro command will be put in the tree under the group. 18. Click on the "Write" button to write the macro command related data to the module. 6.4.
SATEL ETHM-1 Plus 21 7 Remote programming / operating of control panel via Ethernet To enable communication with the control panel to be established from outside of the local network, the module must have a permanent public address. After three consecutive attempts to establish communication with the module using an incorrect key, the module will stop responding for approx. 20 minutes to any attempts to establish communication from the given IP address.
22 ETHM-1 Plus SATEL data encryption key (GUARDX/JAVA KEY). Fig. 12. GUARDX program: parameters for communication via Ethernet. 7.1.3 Initiating connection from GUARDX program 1. In the startup window, "Connection" field, select "GuardX -> ETHM" (Fig. 11), and then click on the "Start" button. 2. In the window that will be displayed after establishing communication, enter the code of administrator / user of the control panel. 7.1.4 Initiating connection from keypad (through control panel) 1.
SATEL ETHM-1 Plus 23 2. In the address field, enter the IP address of ETHM-1 Plus module, and then press ENTER. If a port other than 80 is to be used for communication between the module and the web browser, the address entered must be followed by a colon and the port number. 3. When the login page displays (Fig.
24 ETHM-1 Plus SATEL 7.3 Mobile phone 7.3.1 Configuring ETHM-1 Plus module Enable the GSM option. Program the key for data encryption during communication with the MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO application in the mobile phone (GUARDX/JAVA KEY). Enter the number of TCP port which will be used for communication with the MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO application in the mobile phone, if it is to be different from 7091. 7.3.
SATEL ETHM-1 Plus 25 Fig. 15. MOBILEKPD-2 application (Android system phone): virtual keypad. 8 Specifications Supply voltage ................................................................................................... 12 V DC ±15% Standby current consumption ..........................................................................................70 mA Maximum current consumption........................................................................................