Specifications
SATEL INT-KSG 5
3.2 Programming keypad address without entering service mode
This method is useful when – due to repeating addresses – the keypad support has been
disabled and entering the service mode is impossible.
1. Disconnect keypad power supply (KPD) and signal wires CKM and DTM.
2. Short the keypad terminals CKM and DTM.
3. Switch on keypad power supply.
4. A message indicating the current address will appear on the display.
5. Enter a new address. The keypad will confirm execution of the function by four short and
one long beeps. If it is necessary to change the entered address, touch the key
(keypad restart will follow and a corresponding message will appear on the display).
6. Disconnect the keypad power supply.
7. Open the keypad terminals CKM and DTM.
8. Connect the keypad correctly to the control panel.
4. Keypad identification
The system can only be programmed and operated from keypads that have been identified
by the control panel. The keypad identification function should be run at the first startup of the
control panel, and then each time when adding a new keypad or changing address in
a keypad supported by the control panel. Disconnecting an identified keypad from the bus will
trigger the tamper alarm.
The identification function can be run by using the keypad (S
ERVICE MODE
S
TRUCTURE
H
ARDWARE
I
DENTIFICATION
LCD
KEYPADS ID
.) or D
LOAD
X program („Structure” window
„Hardware” tab „Keypads” branch „Keypads identification” button).
5. Configuration of keypad settings
Parameters and options of the INT-KSG keypad can be programmed by means of any LCD
keypad (S
ERVICE MODE
S
TRUCTURE
H
ARDWARE
LCD
KEYPADS
S
ETTINGS
keypad
name) or D
LOAD
X program ("Structure" window "Hardware" tab "Keypads" branch
keypad name). Creating the macro commands and configuring the screensaver is only
possible in the D
LOAD
X program.
5.1 Keypad parameters and options
Shown in square brackets are the names used in LCD keypads.
Name – individual name of the keypad (up to 16 characters).
Partitions managed by keypad [Partitions] – the partitions which can be armed/disarmed or
alarm in which may be cleared from the keypad. These functions are available to the users
having a suitable authority level and access to those partitions.
Using the service code you can operate all partitions, irrespective of which partitions
are operated by the keypad.
Show alarms of partitions [Alarms] – the partitions, the alarm from which will be indicated
on the keypad by
LED, sound, or a text message.
Show fire alarms of partitions [Fire alarms] – the partitions, the fire alarm from which will be
indicated on the keypad by
LED, sound, or a text message.
CHIME signal of zones [Chime zones] – the zones the violation of which will be indicated by
beeps in the keypad.