Specifications
4 INT-KSG SATEL
Fig. 3. Connection of the keypad to the control panel.
3. Addressing
Each keypad must have an individual address set in it:
from the 0 to 3 range, if it is connected to the INTEGRA 24 or INTEGRA 32 control
panel;
from the 0 to 7 range, if it is connected to the INTEGRA 64, INTEGRA 128,
INTEGRA 128-WRL, INTEGRA 64 Plus or INTEGRA 128 Plus control panel.
By default, address 0 is set in all keypads.
When started, only the control panel with factory default settings can provide support
for all keypads connected to the bus, irrespective of the addresses set in them. In all
other cases, the control panel will block operation of the keypads having identical
addresses.
The address set in the keypad determines the numbers to be given to the keypad zones (see
the I
NSTALLER MANUAL
for INTEGRA or INTEGRA Plus control panels).
3.1 Programming keypad address by mean
s of service function
1. By means of any supported keypad, enter the control panel service mode ([SERVICE
CODE]
S
ERVICE MODE
).
2. Start the function K
EYPADS ADDR
. (S
TRUCTURE
H
ARDWARE
I
DENTIFICATION
K
EYPADS
ADDR
.).
3. The "This LCD address (n, 0-x)" message will appear on the displays of all keypads
connected to the control panel (n – keypad address; 0-x – range of supported addresses).
4. Enter a new address in the selected keypad(s). The address change will be confirmed by
four short and one long beeps.
5. To terminate the address change function, touch the key. The function will be
terminated automatically after 2 minutes from being started. Termination of the function is
equivalent to restarting the keypad (return to the main service mode menu will follow in
the keypad from which the function has been started).