Specifications

30 Installer Manual SATEL
expander). The changes in numeration will only be valid until you start the expander
identification function again.
7. Specifications
7.1 Control panel
Supply voltage ................................................................................... 18 V AC ±15%, 50-60 Hz
Recommended transformer ............................................................................................. 40 VA
Standby current consumption from AC mains ................................................................ 120 mA
Maximum current consumption from AC mains ............................................................. 300 mA
Standby current consumption from battery .................................................................... 280 mA
Maximum current consumption from battery .................................................................. 600 mA
Battery failure voltage threshold ............................................................................... 11 V ±10%
Battery cut-off voltage ........................................................................................... 10.5 V ±10%
Battery charging current .......................................................................................... 400/800 mA
Power supply output current ................................................................................................ 2 A
Power supply output voltage range .................................................................... 10.5…14 V DC
Current-carrying capacity, high-current programmable outputs ................................. 2 A ±10%
Current-carrying capacity, low-current programmable outputs .........................................50 mA
Current-carrying capacity, +KPD output .................................................................. 0.5 A ±10%
Current-carrying capacity, +EX output .................................................................... 0.5 A ±10%
Current-carrying capacity, AUX output .................................................................... 0.5 A ±10%
ABAX system operating frequency band ............................................. 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) ............................................................ up to 500 m
Number of supported wireless devices .................................................................................. 48
Number of supported APT-100 keyfobs ............................................................................... 248
Hardwired programmable zones .............................................................................................. 8
Maximum number of programmable zones .......................................................................... 128
Hardwired programmable outputs ............................................................................................ 8
Maximum number of programmable outputs ........................................................................ 128
Power supply outputs ............................................................................................................... 3
Communication buses.......................................................................................................... 1+1
Keypads .......................................................................................................................... up to 8
Expansion modules ....................................................................................................... up to 32
Objects (subsystems) ............................................................................................................... 8
Partitions ................................................................................................................................ 32
Telephone numbers for messaging ........................................................................................ 16
Voice messages ..................................................................................................................... 16
Text messages ....................................................................................................................... 64
Users + Masters ............................................................................................................. 240 + 8
Timers .................................................................................................................................... 64
Event log .......................................................................................................................... 21503
Security grade according to EN50131 .......................................................................... Grade 2