6. Numeration of zones and outputs in the system
Numbers are automatically assigned to the zones and outputs:
• the hardwired zones and outputs on the control panel board are numbered from 1 to 8.
• numbers of the wireless zones and outputs supported by the INTEGRA 128-WRL control
panel mainboard are set during the procedure of adding wireless devices – free and
available numbers are assigned.
Numeration of wireless devices supported by the INTEGRA 128-WRL control panel
mainboard need not be continuous. For example, if the system includes 8 wireless
zones with numbers 17-24, to which wireless devices are assigned, and the zones
25-32 are already reserved for the expander, then adding a new wireless device will
result in reservation of next 8 zones with numbers 33-40 for wireless devices.
Numbering of the expander zones will remain unchanged. The same rules apply to the
wireless outputs.
• the numbers of keypad zones are determined during the identification procedure, based on
the keypad address (see section NUMERATION OF KEYPAD ZONES p. 14).
• the numbers of zones and outputs in expanders and ACU-100 / ACU-250 controller are
determined during the expander identification procedure. The numbering is dependent on
the expansion module address in the system (zones in expansion module with a lower
address will be given lower numbers than the zones in expansion module with a higher
address).
The control panel reserves 8 zones in the system for each identified expander. The
exceptions are the CA-64 ADR expander and ACU-100 / ACU-250 controller, for which
up to 48 zones can be reserved. In case of the CA-64 ADR expander, the number of
reserved zones depends on the number of detectors with installed CA-64 ADR MOD
module, which are connected to it. In case of ACU-100 / ACU-250, the number of
reserved zones depends on the number of registered wireless devices. In both cases,
the number of reserved zones is a multiple of 8.
The DLOADX program allows you to change the numeration of zones and outputs in
expanders ("Structure" window, "Hardware" tab, "Advanced" button for the selected